Failure Analysis of Electrical Transformers: Construction and Failure Mechanisms

Learn transformer failure analysis through SLI case evidence, from basic schematics and construction drawings to electrical tests, winding microsections and SEM images. The illustrated paper explains open windings, interwinding shorts, dielectric breakdown, conductor spacing, lead fatigue, fretting corrosion, lead finishes and surrounding-circuit faults. Measurements and physical findings connect each electrical symptom with the failure mechanism and the engineering response.

Understanding transformer failures

A basic winding schematic and an exploded construction drawing introduce the primary, secondary, magnetic core, bobbin and terminals. Electrical measurements then identify the winding or isolation path associated with a failure. Case photographs and microsections show how conductor fusion, insulation damage, fatigue and fretting relate to the measured symptoms.

What the paper covers

  • Locating opens and unwanted winding-to-winding or winding-to-shield connections.
  • Recognizing overcurrent fusion and dielectric breakdown.
  • Comparing conductor spacing, insulation thickness and winding construction.
  • Identifying lead fatigue, fretting wear, plating defects and contaminated interfaces.
  • Tracing converter symptoms to board leakage and surrounding-circuit faults.

Analytical methods

Electrical continuity and resistance measurements, inductance comparisons, optical microscopy, radiography, dissection, microsectioning, SEM and EDS.

Author and technical reviewer: Ed Hare, PhD, SEM Lab, Inc. Published and reviewed 4 November 2026.