
Case 2437 ยท Public preview
Excessive Winding Tension Can Consume Transformer Insulation Margin
One transformer population exhibited a high failure rate following reflow soldering.
Optical microscopyMicrosectioningSEMEDSDimensional comparison

What the evidence preview establishes
The strongest correlation with suspect transformers was conductor spacing below the expected two-insulation-thickness margin. Excessive winding tension likely compressed or strained the insulation, with reflow thermal expansion adding stress; variable tape and winding counts documented broader process inconsistency.
Why this case matters
Nominal insulation thickness does not guarantee electrical spacing after winding. Minimum local gap, winding tension, impregnation, turn count, tape construction, and reflow strain should be controlled as a system.
Full evidence reserved for MEMBER and STOREThe complete case includes the evidence sequence, four interpreted figures, alternative explanations, limitations, and practical application guidance.