Case 549 ยท Public preview
A Touch-Panel Contact Can Fail Before the Frame Is Installed
A touch panel gave incorrect cursor positions, prompting comparison of a failed contact with a stock control and a sectioned contact.
Optical microscopyContact comparisonMicrosectioningSEMEDS

What the evidence preview establishes
The spot-silver contact on the failed panel showed poor registration, oxidation, and weak adhesion to the underlying silver thick-film pad. These conditions provide a plausible contact-level explanation for the reported position errors; the report did not isolate one as the sole cause.
Why this case matters
For an intermittent or position-dependent touch-panel response, inspect contact registration, silver condition, and interface adhesion together. A mechanical frame change cannot by itself repair a defective deposited contact.
Full evidence reserved for MEMBER and STOREThe complete case includes the evidence sequence, 4 interpreted figures, alternative explanations, limitations, and practical application guidance.