A Normal Steel Microstructure Does Not Exclude Hydrogen Embrittlement

Zinc-plated spring clips fractured while sustaining a static retaining load.

FractographySEMEDSFailed-to-stock comparisonMetallographic cross-sectioning
Preview image for Case 279

What the evidence preview establishes

The clips most likely failed by hydrogen embrittlement associated with hydrogen exposure during zinc stripping or replating. Residual chloride contamination was a separate corrosion risk.

Why this case matters

When a high-strength plated-steel part breaks under a sustained static load, examine the fracture morphology and plating history even if the bulk microstructure looks normal. Control acid exposure, post-plate baking, and cleaning residues.