Two Independent Glass Failures Compromised a Laser Package

Two field-returned laser devices exhibited fluctuating optical power even though bench electrical measurements were stable.

Electrical testingSEMPackage dissectionFractographyEDS
Preview image for Case 206

What the evidence preview establishes

Fracture of the package lens produced a gross hermeticity breach, while cracked lead seals created an additional leakage path. Moisture ingress and associated electrical leakage provided a credible explanation for unstable laser power.

Why this case matters

When optical output fluctuates but electrical continuity remains stable, evaluate package hermeticity. Examine lens fracture origins, braze interfaces, glass-to-metal seals, and lead-forming marks as a connected mechanical system.