Improvement after Reflow Does Not Necessarily Establish a Solder-Joint Defect

An assembly with reported faults was submitted for evaluation of one IC's solder joints. Hand reflow had reportedly corrected the problem.

As-soldered examinationBSE SEMEDSMicrosectioningMetallurgical etching
Preview image for Case 1689

What the evidence preview establishes

The solder joints appeared acceptable. Excessive tin-lead corrosion product between the leads was identified as the most likely explanation for leakage between signals, rather than a solderability failure.

Why this case matters

Treat reflow recovery as a clue, not proof of a solderability defect. Inspect the spaces between signals and correlate residue chemistry with sound joint sections before choosing solder-process correction over contamination control.