
Case 1890 ยท Public preview
Localized Gold-Plating Pinholes Can Expose Corrosion-Susceptible Contact Metal
Three sets of gold-plated contacts showed corrosion, while a fourth set served as an uncorroded control.
Optical microscopyVariable-pressure BSE SEMEDSTilted-surface examinationMicrosectioningControl comparison

What the evidence preview establishes
Localized pinholes or open blisters in the gold plating were the leading suspected trigger for contact corrosion. Mechanical damage, ionic contaminants, and embedded particles were additional possible contributors; sections did not show a widespread layer failure.
Why this case matters
Inspect contact plating at localized defects, not only at sound cross-sections. Combine tilted or high-magnification surface views with control sections and targeted chemistry, while separating a detected chlorine signal from proof of corrosive chloride.
Full evidence reserved for MEMBER and STOREThe complete case includes the evidence sequence, 4 interpreted figures, alternative explanations, limitations, and practical application guidance.